How to Use Rotary Evaporator or Rotavapor
General rules for usage of rotary evaporators

1. The solvent collection flask of the unit should always be emptied prior use to prevent accidentally mixing of incompatible chemicals. SAFETY FIRST! 

2. The flask with the solution is placed on the rotary evaporator. The use of a bump trap prevents the solution from accidentally splashing into the condenser (and being contaminated). It is highly advisable to start with a clean bump bulb in case something bumps over after all! This would allow the experimenter to recover the solution or solid.

  


3. A metal or Keck clip is used to secure the flask and the bump trap. The green one shown below fits 24/40 ground glass joints. Similar blue clips fit 19/22 joints and the yellow ones fit 14/20 joints, which will most likely used in the lab. If you break the bump trap, you will have to pay for it!

4. The dial on the motor is used for speed control of the flask rotation. A typical rotavap uses a variable speed sparkless induction motor that spins at 0-220 rpm and provides high constant torque. A good setting here is 7-8. 

5. The aspirator vacuum is turned on. On most models, the vacuum on/off control is managed by turning a stopcock at the top of the condenser (left side of the above diagram). This stopcock is later also used to vent the setup after the solvent is removed.

6. The flask is lowered into the water bath (or the water bath is raised to immerse the flask in the warm water. (On most models, a convenient handle (with height locking mechanism) moves the entire condenser/motor/flask assembly up and down. Often the tilt of the condenser assembly can also be adjusted. The water bath temperature should not exceed the boiling point of the solvent!! For small amounts of common solvents the bath heater is not needed.

7. The solvent should start collecting on the condenser and drip into the receiving flask. Some solvents (such as diethyl ether or dichloromethane) are so volatile that they will also evaporate from the receiving flask and be discharged down the drain. To prevent this, a cooling bath on the receiver or (on some models) use a dry-ice condenser can be used. In addition, an additional trap (with dry-ice or liquid nitrogen) can be placed between the vacuum source and the condenser unit. This is particularly important of a membrane pump is used as vacuum source.

8. Once all the solvent evaporated (or whatever is desired at this point), the vacuum is released, . The flask is raised out of the water bath and the spinning is discontinued. 

9. The bump trap has to be cleaned and the receiving flask is emptied upon completion of the evaporation.


Tips and Tricks

Tips and Tricks

Distilled water should be used in the heating bath to minimize the scale build up in the bath which coats the theoris and heating coils. It is very difficult to remove and reduces the efficiency of the bath. In addition, regular tap water will promote the growth of spectacularly disgusting algae colonies, particularly during the summer months. The best protocol is a regular exchange of the water.

To remove algae gunk from the inside of a coiled water condenser, the condenser has to be removed from the rotavap and the coil is soaked in a dilute nitric acid solution for a few hours. After carefully rinsing the insides, the rotavapor is reassembled. All standard safety precautions should be followed when working with nitric acid!

The ground glass joint holding the flask does not need to be greased, but on rare occasions it (or the bump bulb) may get
1486363922
How to Use Rotary Evaporator or Rotavapor General rules for usage of rotary evaporators 1. The solvent collection flask of the unit should always be emptied prior use to prevent accidentally mixing of incompatible chemicals. SAFETY FIRST! 2. The flask with the solution is placed on the rotary evaporator. The use of a bump trap prevents the solution from accidentally splashing into the condenser (and being contaminated). It is highly advisable to start with a clean bump bulb in case something bumps over after all! This would allow the experimenter to recover the solution or solid. 3. A metal or Keck clip is used to secure the flask and the bump trap. The green one shown below fits 24/40 ground glass joints. Similar blue clips fit 19/22 joints and the yellow ones fit 14/20 joints, which will most likely used in the lab. If you break the bump trap, you will have to pay for it! 4. The dial on the motor is used for speed control of the flask rotation. A typical rotavap uses a variable speed sparkless induction motor that spins at 0-220 rpm and provides high constant torque. A good setting here is 7-8. 5. The aspirator vacuum is turned on. On most models, the vacuum on/off control is managed by turning a stopcock at the top of the condenser (left side of the above diagram). This stopcock is later also used to vent the setup after the solvent is removed. 6. The flask is lowered into the water bath (or the water bath is raised to immerse the flask in the warm water. (On most models, a convenient handle (with height locking mechanism) moves the entire condenser/motor/flask assembly up and down. Often the tilt of the condenser assembly can also be adjusted. The water bath temperature should not exceed the boiling point of the solvent!! For small amounts of common solvents the bath heater is not needed. 7. The solvent should start collecting on the condenser and drip into the receiving flask. Some solvents (such as diethyl ether or dichloromethane) are so volatile that they will also evaporate from the receiving flask and be discharged down the drain. To prevent this, a cooling bath on the receiver or (on some models) use a dry-ice condenser can be used. In addition, an additional trap (with dry-ice or liquid nitrogen) can be placed between the vacuum source and the condenser unit. This is particularly important of a membrane pump is used as vacuum source. 8. Once all the solvent evaporated (or whatever is desired at this point), the vacuum is released, . The flask is raised out of the water bath and the spinning is discontinued. 9. The bump trap has to be cleaned and the receiving flask is emptied upon completion of the evaporation. Tips and Tricks Tips and Tricks Distilled water should be used in the heating bath to minimize the scale build up in the bath which coats the theoris and heating coils. It is very difficult to remove and reduces the efficiency of the bath. In addition, regular tap water will promote the growth of spectacularly disgusting algae colonies, particularly during the summer months. The best protocol is a regular exchange of the water. To remove algae gunk from the inside of a coiled water condenser, the condenser has to be removed from the rotavap and the coil is soaked in a dilute nitric acid solution for a few hours. After carefully rinsing the insides, the rotavapor is reassembled. All standard safety precautions should be followed when working with nitric acid! The ground glass joint holding the flask does not need to be greased, but on rare occasions it (or the bump bulb) may get "frozen". Some companies sell special joint clips that can free frozen joints simply by screwing them in one direction. If you are not lucky enough to have these and cannot release the joint you probably want to ask your teaching assistant for advice. If a mechanical pump is used instead of an aspirator to produce a vacuum, a secondary trap has to be used to prevent that the solvent destroys the membrane or is absorbed in the oil.
Rotary Evaporator 50L Senco 

Senco Rotary Evaporator with high Vacuum rate. Our Best performing Rotary Evaporator have big condensing surface Area for efficient distillation. The double loop condenser coil of the rotary evaporator gives higher condensation and receiving rates. Highest Quality perfectly engineered PTFE seal assembly of the rotary evaporator gives extended high life. Simple electronic contorl panel of Senco rotavapor requires lesser maintenance. Strong boro silicate glass parts are used in our rotary evapotor. PT-100 temperature sensor of our rotary evaporator gives high precision temperature control. Ac-Induction motor of our Rotary evaporator is noiseless and maintenance free.

Specifications Rotary Evaporator 50L, Water/Oil Bath; 
- With Patent non-stop tandem receiving tech; 
- With complete flange joint, no glass 


SENCO is a among first brands in China, if featured as
1485775075
Rotary Evaporator 50L Senco Senco Rotary Evaporator with high Vacuum rate. Our Best performing Rotary Evaporator have big condensing surface Area for efficient distillation. The double loop condenser coil of the rotary evaporator gives higher condensation and receiving rates. Highest Quality perfectly engineered PTFE seal assembly of the rotary evaporator gives extended high life. Simple electronic contorl panel of Senco rotavapor requires lesser maintenance. Strong boro silicate glass parts are used in our rotary evapotor. PT-100 temperature sensor of our rotary evaporator gives high precision temperature control. Ac-Induction motor of our Rotary evaporator is noiseless and maintenance free. Specifications Rotary Evaporator 50L, Water/Oil Bath; - With Patent non-stop tandem receiving tech; - With complete flange joint, no glass SENCO is a among first brands in China, if featured as "Safe. Durable. Efficient", and serves middle and high-end users mainly. Features: - High vacuum performance; - Bath Lifting; - Rich function, friendly operation experience, easy assembly structure; - Popular model among Senco rotary evaporators.
Rotary Evaporator supplier  in Hyderabad
 180C Oil Bath

Specifications
2L Senco ROTARY EVAPORATOR with WATER BATH Taper Joint Release Devise 
R206D Senco ROTARY EVAPORATOR SENCO (2L w/Oil Bath) Available Model : R213B, R214B, R206B  Capacity: 0.1~2LBath Temp.: 180 °C max Features:    - High vacuum performance, <133Pa (=1.33 mbar , 1 Torr) is available;- Bath Lifting;- Rich function, friendly operation experience, easy assembly structure;- Popular model among Senco rotary evaporators. 
we provide services all over India 
we have dealers in every states across in India
1486359711
Rotary Evaporator supplier in Hyderabad 180C Oil Bath Specifications 2L Senco ROTARY EVAPORATOR with WATER BATH Taper Joint Release Devise R206D Senco ROTARY EVAPORATOR SENCO (2L w/Oil Bath) Available Model : R213B, R214B, R206B Capacity: 0.1~2LBath Temp.: 180 °C max Features: - High vacuum performance, <133pa (="1.33" mbar="" ,="" 1="" torr)="" is="" available;-="" bath="" lifting;-="" rich="" function,="" friendly="" operation="" experience,="" easy="" assembly="" structure;-="" popular="" model="" among="" senco="" rotary="" evaporators.="" we="" provide="" services="" all="" over="" india="" we="" have="" dealers="" in="" every="" states="" across="" in="">
1486114968
Rotary Evaporator best price in Hyderabad 180C Oil Bath Specifications 2L ROTARY EVAPORATOR with WATER BATH Taper Joint Release Devise R206D ROTARY EVAPORATOR SENCO (2L w/Oil Bath) Available Model : R213B, R214B, R206B Capacity: 0.1~2LBath Temp.: 180 °C max Features: - High vacuum performance, <133pa (="1.33" mbar="" ,="" 1="" torr)="" is="" available;-="" bath="" lifting;-="" rich="" function,="" friendly="" operation="" experience,="" easy="" assembly="" structure;-="" popular="" model="" among="" senco="" rotary="" evaporators.="" we="" provide="" services="" all="" over="" india="" we="" have="" dealers="" in="" every="" states="" across="" in="">
Rotavapor in Hyderabad senco Rotary Evaporator 10 Litre

Senco Rotary Evaporator with high Vacuum rate. Our Best performing Rotary Evaporator have big condensing surface Area for efficient distillation. The double loop condenser coil of the rotary evaporator gives higher condensation and receiving rates. Highest Quality perfectly engineered PTFE seal assembly of the rotary evaporator gives extended high life. Simple electronic control panel of Senco rotavapor requires lesser maintenance. Strong boro silicate glass parts are used in our rotary evaporator. PT-100 temperature sensor of our rotary evaporator gives high precision temperature control. Ac-Induction motor of our Rotary evaporator is noiseless and maintenance free.
1485762519
Rotavapor in Hyderabad senco Rotary Evaporator 10 Litre Senco Rotary Evaporator with high Vacuum rate. Our Best performing Rotary Evaporator have big condensing surface Area for efficient distillation. The double loop condenser coil of the rotary evaporator gives higher condensation and receiving rates. Highest Quality perfectly engineered PTFE seal assembly of the rotary evaporator gives extended high life. Simple electronic control panel of Senco rotavapor requires lesser maintenance. Strong boro silicate glass parts are used in our rotary evaporator. PT-100 temperature sensor of our rotary evaporator gives high precision temperature control. Ac-Induction motor of our Rotary evaporator is noiseless and maintenance free.

Our timings

[IS_BIZ_OPEN] Mon: 9:00AM  -  6:00PM
[IS_BIZ_OPEN] Tue: 9:00AM  -  6:00PM
[IS_BIZ_OPEN] Wed: 9:00AM  -  6:00PM
[IS_BIZ_OPEN] Thu: 9:00AM  -  6:00PM
[IS_BIZ_OPEN] Fri: 9:00AM  -  6:00PM
[IS_BIZ_OPEN] Sat: 9:00AM  -  6:00PM
[IS_BIZ_OPEN] Sun: Closed  -  Closed

Contact

Kd Traders Furquan Siddique(Proprietor) 10-2-485, Vijay Nagar Colony, Asif Nagar, - 500028, Telangana
+91 8079442926  or   or   
Please keep or 0 before the
number when you dial.
Share Tweet
17.4480788908933 78.4305517232567 KD Traders 9290788196 Kd Traders Furquan Siddique(Proprietor) 10-2-485, Vijay Nagar Colony, Asif Nagar, - 500028, Telangana
False

SUBSCRIBE

5860b1ff68346f1df84141e3KDTRADERSELECTRONICSHYDERABAD57c3c1a65d64370d7cf4eb17